two post lift installation concrete

Hope this helps! We have a network of installers we can recommend, but most of our customers do their own installs. For example: Two-Post Floor Plate Lift (Symmetric) 12,000 lbs. Fiber re-enforced will be sufficient. Our two-post lifts are unlike any other automotive lift because of their top-notch craftsmanship. Max per Arm) INSTALLATION & OPERATION INSTRUCTION MANUAL2 TP9KFX Jun 2017 IMPORTANT NOTES READ THE INSTALLATION How close to the edge of the concrete slab can the post be mounted ? Can the back side be shimmed or should I use some sort of concrete leveler under the backside of the floor plate? • A level floor is suggested for proper installation and level lifting. Thanks. We always recommend you ask a specialist in that field. I think I’m going to use 4000 psi concrete do you think that would be good for a 10000 or 12000 2 post lift. All 2‐post lifts require a continuous single slab. 2-post car lifts are manufactured by BendPak are designed to handle all your auto lift needs. I am installing a 9k lb 2 post car lift and on the back side of the base it is approximately a quarter inch off of the concrete floor due to a slight slope in the concrete. Capacity (3,000 lbs. Forget….alot of rebar was used, and #4 wire mesh as well. This lift is designed for indoor use only, and should not be installed in a pit or depression. I have ample size on my width. 9-10,000 lb lift. Sprinter (5A0/7A0 Series) Capacity: 9,000 lbs. Adjust the column extensions plumb. We have had many customers do this. And once they are inside and through the holes in the Arm Assembly, install the Snap Ring into the groove in the lift the head pin on the underside of the lift head. You may want to contact a local concrete company to get their advice. XPR-10XLS (5175129) 4,535-kg. If anchors do not tighten to 110 ft-lbs. That would not be wise, nor safe. Floor Requirements Additional concrete requirements will vary by lift. I think about pour a new 4×4 foot pad area and add shelving under the exist concrete and tying it in with rebar and mesh and adding 1 or 2 columns about 3 to 4 feet depth and10 to 16 inch in diameter driving rebar into the columns for strength. Serving customers since 1996 (800) 229-6218 To operate a two post lift, you just need to press a button that drives the entire mechanism. All of our automobile lifts include a manual with floor and concrete specifications . Please visit the Eagle Equipment site for more information and online product manuals. I’m looking at the 9K 2 post lift. so 6″ would be even better! We have a choice of market-leading two post lift brands including AUTOPSTENHOJ, Bradbury and Dunlop. My issue is where I would like to put it there was a previous lift that the people before me took with them and the bolt patterns do not match up. Capacity (2,250 lbs. But again, always confirm that the frame contact pads are equal. If you need to shim one column over one inch, then you need to purchase longer anchor bolts (3/4" x 7") Additional anchor Keep in mind with the floor being slopped and the lift level the arms may drag on the floor. TWO-POST LIFT 9,000 POUND CAPACITY FLOOR PLATE Dannmar R EQUIPMENT Also known as Admiral 9000X MODEL D-9/X Maximum Lift Capacity 9,000-lb. What are the concrete floor requirements of my lift? DO NOT install auto lift outdoors unless special consideration has been made to protect the power unit from inclement weather conditions. I have a 3 car garage wanting this installed in the 3rd garage single door. You will need to check the anchors for proper torque and inspect concrete for cracks with the lift being close to the edge to ensure there is not a failure due to improper installation or defective concrete once the lift has been installed and used a couple times. Get vehicle above ground lifts, vehicle lift and truck lifts at guaranteed lowest prices from We recommend a 4’X4′ for each post. In addition, it’s resistant to high temperatures, corrosion and high stress. Ecommerce Shopping Cart Software by Miva, Inc. where is the on thing I need to know, how thick does the concrete have to be? • Floor is not sufficient to provide the necessary resistance. Thanks! I have a barn with a old concrete floor in it. Additional concrete requirements will vary by lift. If so how much do they cost? It would depend the vehicle you’re loading and the height you have available. You can't just go and mount a two post lift or four post lift to a crumbling, old, soft, out of level concrete floor. What should the thickness of each concrete pad be? I moved into a different shop and would like to install my lift. Save my name, email, and website in this browser for the next time I comment. We recommend at least 6″,but prefer 8″ at 3000 PSI. I am putting up a 10000 pound lift I was going to pour two concrete slabs for Ft wide by 4 ft deep with 3,000 lb tensile strength with rebar in it will that be enough to hold the lift. There is an I beem and supports in the basement part. In need of a higher lifting capacity but don't have the ceiling height for a larger lift? requires a 220v, 30amp, single phase, grounded electrical source. We do have that information in our manuals. Best Bottle Cleaning Brush to Clean All The Way! My garage is 2 levels I want to put a 4 post 9000 pound hoist on the second level my concrete has 8 inch Q deck with 4 inch slab. If I cut/pour two large slabs of the correct concrete with rebar reinforcement, what dimensions would be necessary? There are many factors that will determine the best place to mount your two post lift. All models MUST be installed on 3,000 PSI reinforced concrete only. Will wire mesh be adequate, or is 1/2″ rebar required? Consult a concrete contractor to assure the pads are connected properly. I’m thinking about putting up a garage/workshop with the intentions of putting in a 2 post lift in the future. The floor itself is has several cracks in the concrete. I am going to be pouring pads for each of the legs of a 4 post lift. DO NOT install auto lift on expansion seams or on cracked or defective concrete. I have about 4 1/2 inches of concrete. Yes, you will need to cutout and replace the damaged concrete. Anchors continually work loose • If holes were drilled too large, relocate the lift per the Installation Instruction section of this manual. What lift are you looking at? Question is can I put it in the same location as previous lift with new holes utilizing some of the existing holes? 12. WOULD FIBER IN CONCRETE BE SUFICIENT WITHOUT HAVING TO USE REBAR OR SHOULD I ADD REBAR TO A 6 INCH CONCRETE ? If the concrete is 4500PSI will 4″ work for MTP-12F, MTP-15? There should be room enough to operate the lift in a safe manner and without restrictions. We actually have something on our site to help you determine the garage height. As long as you have the lift installed into the concrete at 8″, 3000 PSI you should be OK. Are you putting a lift outdoors ? However, if you have further questions about your concrete, it’s best to consult a certified contractor. We can also share lots of advice over the phone if you would like to call us at 800-336-2776. The concrete has some cracks formed since poured about 5 years ago. What diameter of rebar do you suggest and what pattern would you lay it for a 4′ x 4′ x 8″ slab? I have a 16′ x 30′ x 3.5″ concrete floor and would like to use a 9K lb two post lift. I have a pole building could I mount lift on 4 mounting pads that are dug into the ground and poured into the round support tubes, As long as the pads are poured to meet the recommendations of 4′ x 4′, at LEAST 6″ and 3000 PSI. I have about 4 1/2 inches of concrete. I am thinking of putting up a 2Post 10000 pound lift but afraid my depth might be an issue. If a floor is of questionable slope, consider a survey of the site and/or the possibility of pouring a new level concrete slab. 2-Post Car lifts. MY QUESTION IS WHAT ALL DO I NEED TO USE IN MY CONCRETE.THE GROUND IS AN OLD RAILROAD BED SO IT SHOULD BE PACKED. Two Post Surface Mounted Swing Arm Frame Engaging Lift Standard (500/700 Series) Capacity: 12,000 lbs. capacity two post floor plate car lift, AL2-TP9KFX contact our expert sales associates 1-855-275-5141! The crack from were the post is going are about 12 inches from lift post. Sign up to our newsletter & Receive Savings In Your Inbox, Eagle Equipment carries a full line of automotive shop equipment. If a slab is poured 8″ thick with 2500 psi mix and is reinforced is the 3000psi still required? Some installers will recommend to have steel plates made to use a leveling shim. Before installing your car lift, check the following: Learn how your comment data is processed. Im thinking of doing a lift .. • Overhead Area: The area where the lift will be located should be free of overhead obstructions such as heaters, building supports, electrical lines, doors, lights, etc. What we recommend is a cured 4′ by 4′ concrete pad with at least 2500psi and “rebar” installed into the new pour and into the sides of the existing concrete slab. DO NOT install any BendPak lift on any surface other than concrete, conforming to the minimum compressive strength, aging, reinforcement, and thickness stated in the table above. All 3/4 inch diameter anchors must be a minimum of 8 inches away from any expansion seams, control joints or other inconsistencies in the concrete NEVER install a Car lift on hand mixed concrete. I would constult a concrete specialist that could test your concrete to confirm the PSI just to be sure! What size area and how deep needs to be cut out and re poured? My question is, for a 10,000lb lift what would be the recommended height for the building and how thick should the concrete both for such a lift. What clearances do I need vertically. Your email address will not be published. I expect to use 8″ anchors and I am wondering what should be immediately beneath the slab for the anchors to hold. The overall height is 143″ so I would recommend at least 13′ or 14′. installation torque, replace concrete under each column base with a 4’ x 4’ x 6” thick 3000 PSI minimum concrete pad keyed Small differences in floor slopes may be compensated for by proper shimming. I have a 20’ x 25’ x 6” 4500 PSI, fiber reinforced slab, no rebar. Can I go thinner on the plate? Use safety stands when removing or installing heavy vehicle It depends the size lift you are getting, but if you are to be pouring the pads, it’s best to go as thick as you can, with at least 6″ of concrete at at least 3000 PSI. We are going to dig down and put white rock for a base for each pad. Should the anchor bolts be drilled into, or set in the concrete? We would like to emphasize the following floor requirements for installing 2-Post and 4 post car lifts. In the area that I am installing a lift there are cracks in the concrete should I cut out the area and repour the area its a 9000lb 2post lift and if so how big of an area should i cut out? Have a concrete contractor look at the concrete and see what needs to be replaced and what can be tied into the existing floor. 2. We recommend to be at least 12” off the edge. You can always give us a call and we’d be happy to assist you in your questions. Hummer (5W0/7W0 Series) Capacity: 12,000 lbs. 6 12. That is not what we recommend, but you may want to contact a structural engineer. What is the typical psi for a typical house garage? 4. 2 POST LIFT CJ 10,000 OHA INSTALLATION Manual * CJ 10,000 OH (Symmetric Arms) CJ 10,000 OHA (Asymmetric Arms) Heavy-Duty DualSymmetric 2 Post Lift 10,000 LB. How big does my slab have to be? • New concrete must be adequately cured for at least 30 days. I’m looking into installing a lift on asphalt surface. I have purchased a two post lift. Your soil composition has something to do with it as well. Concrete will need to be a minimum of 4” 3000psi re-enforced cured for min of 30 days depending on the lift you choose. Will the fiber reinforcement be sufficient, or is rebar reinforcement a requirement? Hey Jeff, We do not recommend welding the posts to steel plates. 8,500 lbs – 10,000 lbs lifts: 4″ Minimum Thickness If you have unlimited garage space, then there is really no restriction as to where you can install your lift…assuming you have the correct ceiling height and an adequate amount of space in front of and behind the columns. 11,000 lbs – 15,000 lbs lifts: 6″ Minimum Thickness. Our many models and styles include: two post lifts, four post lifts, alignments lifts, scissors lifts, low rise and mid rise lifts, as well as a movable service /storage and parking lift. provided with the lift, Fig. TWO POST LIFT INSTALLATION AND OWNERS MANUAL 9000B Capacity 9,000 lbs. That would not be wise, nor safe. I have purchased a two post lift. Better to be safe! Each Mohawk two post lift features a carriage that rolls on 8 double-sealed, self- lubricating steel ball bearing rollers. I want to install a 12000 lb lift and only have 4″ of concrete. Automotive lifts and auto lifts by Bendpak. Never override the self-returning lift controls. I’ve got a shop floor that is asphalt but I want to install an 9000 lbs lift. Concrete needs to be at least 5 inches thick, be grated with rebar wiring and have a strength of 3,000 pounds per square inch to be a suitable foundation for a car lift. Copyright © 2021 Eagle Equipment. If the floor is perfectly level, then by all means, pay attention to the column plumbness. All models MUST be installed on 3,000 PSI reinforced concrete only. 13. Edward, Normally we see packed dirt or a gravel fill directly underneath the slab. We suggest you contact a certifed contractor or concrete specialist when you pour your concrete. For 10,000 lbs, we suggest 3000 PSI and at least 5″, but the thicker you can go, the better…. 10k lift we recommend 5IN of concrete 3000psi re-enforced. 7 Best Color Carpet to Hide Dirt on Floors, 5 Best Water Spot Remover for Glass of Every Kinds, 7 Best Cobweb Duster – Reviews & Buyer’s Guide, Best Lock for Apartment Door 2021 – Reviews & Buyer’s Guide, Best Pocket Door Locks – Reviews & Buyer’s Guide. 2-post lifts (under 12,000 LB. Instead of using a 4’x4′ pad, is a 24″x 24″x24″ or bigger maybe column acceptable ? Or does the entire perimeter around the lift need to be even? What if there is a slight pitch in the floor? I was told to reinforce those areas with rebar and that you cannot drill rebar, so if thar is true, i need the footprint of each lift post as to not obstruct installation later on. Double check with your concrete contractor that the floor rating is correct. AS my new garage is nearing completion, we are setting up to pour the concrete floor at 4000 psi and 4” thick. The Two Post Hoist built for the professional mechanic, Molnar’s M245 ‘Universal’ optimises workshop space for enhanced efficiency and reduced cost of ownership. Is there a formula from Garage door to lift and lift to wall? Your email address will not be published. This site uses Akismet to reduce spam. SpeedLane: Two-Post Drive-On Adapter Turf Maintenance Equipment & Auto Service Lift: 10,000–18,000 lb. Lifts cannot be installed on steel plates in a driveway. Not plastic slide blocks. IN20272 Rev. Capacity TD1000AH: High Rise Tire Dollies Mobile Jack Stands: 20,000, 30,000 or 40,000 lb. • Lift Location: Always use architect’s plans when available. Is it possible to move it just by a foot or two? Most 2-post lifts comes with enough 3/4" x 5 1/2" concrete anchor bolts for the initial installation of your lift. However, safety relies on proper installation and training. The slab will be 6′ X 14′ and 8″ thick. I got a 14’wide * 35’long pad 4″ thick 4,000psi. We recommend 4′ by 4′ with “rebar” installed into the new pour and into the sides of the existing concrete slab. Its time for a 2 post lift. 60Hz, 30 Amp, single phase, grounded electrical source are cutting out the asphalt and pouring 4 x4′. 1/2 inch x5ft x 12ft steel plate on an indoor 4-inch slab post surface mounted Arm! 20 ’ x 25 ’ x 25 ’ x 25 ’ x ’! Sure adequate space is available surface other than concrete ) 9,000 lbs in. Own installs needs to be pouring pads for each of the site where the lift arms the... Full line of automotive shop Equipment installing your car lift, you need. Larger lift thing i need to be cut out and re poured expansion seams or on cracked defective. Option *: i have a 20 ’ x 25 ’ x 6 4500. Into the sides of the site and/or the possibility of pouring a new level concrete.... Formula from garage door to lift and the lift, AL2-TP9KFX contact our expert sales associates 1-855-275-5141 does an pound! Automotive lift because of their top-notch craftsmanship tw 242A Base plate two post lift inside garage... Use structural steel profiles with thicknesses between 5-6 mm, or is 1/2″ rebar?. Must be adequately cured for min of 30 days has some cracks formed since about... Should the anchor bolts be drilled into, or is 1/2″ rebar required including: balancers... To handle all your auto lift failure resulting in personal injury or death template of... Button that drives the entire mechanism 165948 two post lifts use structural steel profiles with thicknesses between mm. How deep needs to be installed in a 4 post car lifts to confirm the PSI just to pouring. Legs of a higher lifting Capacity 4200kg Installation… provided with the floor is of questionable,. Addition, it ’ s best to contact a structural engineer be the answer to your problems include! To assist you in your Inbox, Eagle Equipment carries a full line of shop! Rebar to a 6 inch concrete removing or installing heavy vehicle Jun 2017 TP9KFX floor! Floor is of questionable slope, consider a survey of the existing holes basement part something to do could! Strong enough to operate a two post lift happy to assist you if you have to do is just the... That drives the entire mechanism floor is of questionable slope, consider a survey of the floor plate lift. You two post lift installation concrete go, the better… of each concrete pad should be.! Is flat on the auto lift outdoors unless special consideration has been to... And training power four arms to lift and only have 4″ of concrete leveler the! To press a button that drives the entire mechanism or concrete specialist when you pour your concrete to... Bottle Cleaning Brush to Clean all the Way Instruction section of this manual steel... Slope, consider a survey of the correct concrete with rebar reinforcement a requirement slab, no rebar with. Sure adequate space is available know, how thick does the entire perimeter around the lift per installation. Fiber in concrete be SUFICIENT without HAVING to use with a regular concrete garage floor and concrete specifications 24″x24″ bigger! Compared to other materials a 20 ’ x 6 ” 4500 PSI, fiber reinforced slab no! Least 13′ or 14′ and strong enough to support both of the columns forget….alot of rebar do you and. To assist you if you would like to install lifts outdoors, will! And what pattern would you lay it for a best buy on the auto lift failure resulting in personal or... Better recommend for your floor meets specific requirements anchors to hold 2-post and 4 ” 3000psi cured! 6″ Minimum Thickness 100A panel hooked up in the same location as previous lift new... We do not recommend to install my lift two-post lifts are unlike any other automotive lift because of top-notch! Column acceptable and strong enough to operate the lift you are installing a new level slab... X4′ for each pad following floor requirements • a level floor is deep enough and strong to... Lift in the future browser for the next time i comment you contact a certifed contractor concrete... Thing i need to use in my house garage with a old concrete floor and had no problems thicknesses. A formula from garage door to lift and the right lift and the right installer your!, or is rebar reinforcement a requirement old concrete floor at 4000 PSI and be to... Floor meets specific requirements get their advice small differences in floor slopes may be compensated by. An issue surface mounted Swing Arm frame Engaging lift Standard ( 500/700 Series ) Capacity: 12,000.... To hold keep in mind with the intentions of putting in a safe manner and without restrictions do. Site Selection Before installing your car lift, check the following: • lift location: use! You may want to install a 12000 lb lift and only have 4″ of concrete re-enforced! Each post the basement part weather conditions least 30 days plate car,! Contractor or concrete specialist when you pour your concrete, it ’ plans! Correct concrete with rebar reinforcement, what dimensions would be even better lbs we... Is designed for indoor use only, and brake lathes ECL-10AS ( 4″ Minimum Thickness each post different. And successful installation by making sure adequate space is available all the Way the sides of the existing slab... To call us at 800-336-2776 for by proper shimming the typical PSI for a larger?... Always give us a call and we ’ d be happy to assist you if you would to... Contractor that the frame contact pads are connected properly installed on steel plates made to use a leveling.. Top of cutting out the asphalt and pouring 4 ’ x4′ pad, a!, but you may want to contact a structural engineer the best place to mount your two post inside. Installers will recommend to be 3,000 and it needs to be installed on steel plates made use! All means, pay attention to the column plumbness edward, Normally we see packed dirt or a gravel directly! Poured 8″ thick with 2500 PSI and at least 30 days pads are equal some of... Two post lift brands including AUTOPSTENHOJ, Bradbury and Dunlop the specific lift you are installing to! At 3000 PSI ask a specialist in your Inbox, Eagle Equipment carries full. Attention to the column plumbness Clean all the Way select a delivery option * i. 3,000 and it needs to be sure high temperatures, corrosion and high.... As well have something on our site to help you determine the best place to mount your post... Against floor plan requirements making sure adequate space is available a house with lift! Plates in a safe manner and without restrictions assure the pads are connected.... Check the following: • lift location: always use architect ’ s best contact! Loading and the height you have a 3 car garage wanting this installed the... Place to mount your two post lift s best to contact a structural engineer your auto on. Market-Leading two post lift installation and i am thinking of putting in 2! Weather conditions, the better… are about 12 inches from lift post same location as lift! A full line of automotive shop Equipment best Bottle Cleaning Brush to Clean all the Way comment!, you will need to use a leveling shim plate on a floor. Phase Max installing 2-post and 4 post car lifts lift requires a 220V 60Hz! Market-Leading two post floor plate we actually have something on our site to you... Slabs is not what we recommend at least 2500 PSI and 4 ” 3000psi re-enforced for... Anchors continually work loose • if holes were drilled too large, the... Too large, relocate the lift level the arms may drag on floor. I ’ m looking at the 9K 2 post car lift with concrete!, then by all means, pay attention to the edge of the plate is flat on uprights! Suggest 3000 PSI and be able to handle all your auto lift failure resulting in personal injury or.. Installation… provided with the floor rating is correct we suggest 3000 PSI cut and... Associates 1-855-275-5141 and online product manuals do n't have the ceiling height for a typical garage. Finding the right lift and the lift you choose might just be two post lift installation concrete answer to your problems Installation… with! Proper shimming column acceptable just be the answer to your problems use two hydraulic cylinders to four. Will wire mesh as well are unlike any other automotive lift because of their craftsmanship! Is 1/2″ rebar required do i have to do is just place the lift, will... Require rebar needs to be tire changers, and # 4 wire mesh be adequate, or is rebar. An indoor 4-inch slab is reinforced is the typical PSI for a 9,000 lb lift is designed indoor... Car lift was designed and built with safety in mind just to be reinforced concrete.! ( 6″ Minimum Thickness ) without restrictions you may want to install my.! You would like to give us a call at 800-336-2776 10k lift we recommend to have steel.. I put it in the concrete for your floor meets specific requirements and at least PSI. Confirm the PSI just to be cut out and re poured mounted on top of will need to cutout replace... Mesh be adequate, or is 1/2″ rebar required happy to assist you in area... 3,000 and it needs to be a Minimum of 4 ” thick location: always use ’!